Free and Force Convection Apparatus

Free and Force Convection Apparatus

Product Code : EL-HAMTLE-10761

Free and Force Convection Apparatus (code EL-HAMTLE-10761) is a trainer for comparing free and forced convection on heating elements of different geometry inserted in a vertical air duct, through which an axial fan on top draws ambient air. Four heating elements are available, two of which can also be run outside the duct for free convection, and the 120 × 120 mm duct, a fan of up to 500 m³/h and USB-linked software allow Nusselt and Reynolds numbers to be determined.

Get a quote: use the Add To Cart enquiry button below, or send your quantity and delivery location through the contact page.

Specifications

ParameterDetail
UseBasic experiments on free and forced convection on various heating elements
Air ductVertical, with heating elements inserted into it
FanAxial fan on top of the duct, drawing ambient air through it
Heating elementsFour, of different geometries; two can be operated outside the duct for free convection
Element designHeat released only at the surface; compact, for rapid heating and short experiment times
SensorsTemperature at the duct inlet and outlet; air velocity, to determine the airflow rate
ControlHeating power and flow rate adjusted and displayed via the software
PC connectionUSB
Software functionsEducational software, data acquisition, system operation
ExperimentsNusselt number; free and forced convection; flow formation and heat transfer; transient heating process
GeometriesFlat plate, cylinder, tube bundle
Characteristic variablesNusselt number, Reynolds number
Air duct
Flow cross-section120 × 120 mm
HeightApprox. 0.6 m
Element temperature limitation90 °C
Tube bundle
Number of tubes23
Heated tubeOne tube in variable position
Heating power20 W
Heat transfer area0.001 m²
Cylinder with even surface temperature
Heating power20 W
Heat transfer area0.0112 m²
Plate
Heating power40 W
Heat transfer area2 × 0.01 m²
Cylinder with heating foil, for local heat transfer
Heating power40 W
Heat transfer area0.0112 m²
Axial fan
Max. flow rate500 m³/h
Max. pressure differenceApprox. 950 Pa
Power consumption90 W
Measuring ranges
Air velocity0–10 m/s
Temperature4 × 0–325 °C
Heating power0–50 W
Requirements, dimensions and weight
Power supply230 V, 50 Hz, 1 phase; 230 V, 60 Hz, 1 phase; 120 V, 60 Hz, 1 phase
Dimensions (L × W × H)Approx. 800 × 600 × 800 mm
WeightApprox. 30 kg
Supply
Product codeEL-HAMTLE-10761
ManufacturerEngineering Lab Equipment, Ambala, Haryana, India

What Is the Free and Force Convection Apparatus Used For?

Convection is heat carried away from a surface by a moving fluid. In free convection the air moves only because it rises as it warms; in forced convection a fan drives it past the surface. Students choose a flat plate, cylinder or tube bundle element, fit it in the duct, and set the heating power and fan flow in the software, reading inlet and outlet air temperatures and air velocity. Running one of the two outside elements with no airflow gives the free convection case. The heating-foil cylinder shows how heat transfer varies around its surface, and moving the heated tube within the 23-tube bundle shows the effect of its position.

What to Specify When Ordering

  • Quantity — the number of convection apparatus sets required.
  • Supply rating — single-phase 230 V, 50 Hz, 230 V, 60 Hz or 120 V, 60 Hz.

Frequently Asked Questions

What is the difference between free and forced convection?
In free convection, air moves only because it rises as it is warmed; in forced convection, a fan drives the air past the surface, which generally increases heat transfer.

Which heating elements are available?
Four elements are available: a tube bundle of 23 tubes with one heated tube in variable position, a cylinder with an even surface temperature, a flat plate, and a cylinder with heating foil for local heat transfer.

Can free convection be tested outside the duct?
Yes. Two of the four heating elements can be operated outside the air duct, so free convection can be studied without the fan-driven airflow.

What does the axial fan deliver?
The axial fan on top of the 120 × 120 mm duct gives a maximum flow rate of 500 m³/h and a pressure difference of approx. 950 Pa, drawing 90 W.

What do the Nusselt and Reynolds numbers describe?
The Nusselt number compares heat transferred by convection with that by conduction alone, and the Reynolds number characterises the flow, indicating whether it is laminar or turbulent.

How is an order placed for this apparatus?
Click the Add To Cart enquiry button on this page, or use the contact page to send the number of units needed and where they are to be delivered.

OEM Manufacturer

The Free and Force Convection Apparatus is made by Engineering Lab Equipment (Engineering Labs Equipment Pvt Ltd) at its works at Plot No. 43, Industrial Park, Sector 2, Growth Center, Saha, District Ambala, Haryana, India. The company designs, makes and tests heat and mass transfer apparatus for conduction, convection, radiation and heat exchangers for engineering colleges, polytechnics, technical training institutes and research laboratories in India and overseas, and can build equipment to an institution's own requirements. Tender and OEM enquiries are handled through the Tenders/OEM page.

Related Heat and Mass Transfer Equipment

See the full Heat and Mass Transfer Lab Equipment range or all Mechanical Engineering Lab Equipment.

Request a Quote

For this and other heat and mass transfer lab equipment, schools and colleges can contact Engineering Lab Equipment, a manufacturer, supplier and exporter based in Ambala, India. To ask for a quotation, send the number of apparatus sets and the supply voltage and frequency on site and your delivery location through the contact page, or use the Add To Cart enquiry button on this page.

Last updated: October 2026

   

Office Address

Works:Engineering Labs Equipment Pvt Ltd Plot No. 43, Industrial Park, Sector 2, Growth Center, Saha, District Ambala, Haryana. Ambala, Haryana, India

[email protected]