Multi Heat Exchanger with Data Acquisition

Multi Heat Exchanger with Data Acquisition

Product Code : EL-HAMTLE-10764

Multi Heat Exchanger with Data Acquisition (code EL-HAMTLE-10764) is an experimental apparatus for studying concentric tube, shell and tube, and plate heat exchangers under parallel or counter flow, together with batch-type heat transfer in a stainless steel jacketed vessel with coil and stirrer. A service module with hot water tank, pump, 3000 W heater, 14 temperature points, hot and cold water flow meters and a temperature control unit feeds whichever exchanger is selected by opening a valve.

Get a quote: use the Add To Cart enquiry button below, or send your quantity and delivery location through the contact page.

Specifications

ParameterDetail
UseStudying three types of heat exchanger under parallel or counter flow conditions
Exchanger selectionBy opening a valve
Flow direction changeParallel to counter flow by switching two flexible hoses
Heat exchangers
Concentric tube2 sections of stainless steel inner tube with clear acrylic casing
Shell and tubeStainless steel inner tubes with clear acrylic casing
PlateStainless steel multiple plates
Service module
Hot waterHot water tank and transfer pump
Heater3000 W
Temperature points14
Flow metersHot water and cold water
Temperature control unit1
Jacketed vessel
VesselStainless steel jacketed vessel with coil and stirrer
Vessel contentWith a temperature sensor
Jacket heat transfer areaApprox. 600 cm²
Coil heat transfer areaApprox. 350 cm²
Stirrer0–500 rpm
Instrumentation and software
InstrumentationMicroprocessor-based, housed in the unit
PC connectionUSB
Software functionsEducational software, data acquisition, system operation
ExperimentsComparison of the three exchanger types; parallel and counter flow; batch heat transfer in the jacketed vessel; heat transfer coefficient; effects of flow rate and temperature difference
Measuring ranges
Temperature2 × 0–325 °C
Heating power0–3000 W
Requirements, dimensions and weight
WaterOutside water supply required
Power supply230 V, 50 Hz, 1 phase; 230 V, 60 Hz, 1 phase; 120 V, 60 Hz, 1 phase
Dimensions (L × W × H)Approx. 1200 × 600 × 800 mm
WeightApprox. 55 kg
Supply
Product codeEL-HAMTLE-10764
ManufacturerEngineering Lab Equipment, Ambala, Haryana, India

What Is the Multi Heat Exchanger with Data Acquisition Used For?

A heat exchanger passes heat from a hot fluid to a cold one through a separating wall, and its type and flow arrangement decide how much heat is transferred for a given size. Students heat water in the service module tank, open the valve for the concentric tube, shell and tube or plate exchanger, set the hot and cold flows on the flow meters and record the temperatures; switching two hoses changes parallel flow to counter flow. From the temperature changes and flow rates they work out the heat duty and the heat transfer coefficient of each type. The jacketed vessel then shows batch heating of a stirred liquid through a jacket or coil.

What to Specify When Ordering

  • Quantity — the number of multi exchanger units required.
  • Single-phase supply — 230 V at 50 Hz, 230 V at 60 Hz or 120 V at 60 Hz.

Frequently Asked Questions

Which heat exchangers are included?
There are three: a concentric tube exchanger with 2 sections of stainless steel inner tube, a shell and tube exchanger with stainless steel inner tubes, both cased in clear acrylic, and a plate exchanger with stainless steel plates.

How is the flow changed from parallel to counter flow?
Changing from parallel to counter flow is done by switching two flexible hoses, and the exchanger to be used is chosen simply by opening a valve.

What does the jacketed vessel demonstrate?
The stainless steel jacketed vessel, with coil, stirrer of 0 to 500 rpm and temperature sensor, demonstrates batch-type heat transfer through its jacket of approx. 600 cm² and coil of approx. 350 cm².

Why does counter flow usually transfer more heat?
In counter flow the two streams enter at opposite ends, so a temperature difference is kept along the whole length and the cold stream can leave hotter than the hot stream's outlet.

What should an overseas buyer include in an enquiry?
Give the quantity, the destination country and the port or city of delivery, the delivery terms wanted (for example FOB or CIF), any packing requirements and the tender reference if there is one.

What does the service module contain?
It holds a hot water tank and pump, a 3000 W heater, 14 temperature points, flow meters for hot and cold water and one temperature control unit; an outside water supply is also needed.

OEM Manufacturer

The Multi Heat Exchanger with Data Acquisition is made by Engineering Lab Equipment (Engineering Labs Equipment Pvt Ltd) at its works at Plot No. 43, Industrial Park, Sector 2, Growth Center, Saha, District Ambala, Haryana, India. The company designs, makes and tests heat and mass transfer apparatus for conduction, convection, radiation and heat exchangers for engineering colleges, polytechnics, technical training institutes and research laboratories in India and overseas, and can build equipment to an institution's own requirements. Tender and OEM enquiries are handled through the Tenders/OEM page.

Related Heat and Mass Transfer Equipment

See the full Heat and Mass Transfer Lab Equipment range or all Mechanical Engineering Lab Equipment.

Request a Quote

For this and other heat and mass transfer lab equipment, schools and colleges can contact Engineering Lab Equipment, a manufacturer, supplier and exporter based in Ambala, India. To ask for a quotation, send the number of multi heat exchanger units and the supply voltage required and your delivery location through the contact page, or use the Add To Cart enquiry button on this page.

Last updated: October 2026

   

Office Address

Works:Engineering Labs Equipment Pvt Ltd Plot No. 43, Industrial Park, Sector 2, Growth Center, Saha, District Ambala, Haryana. Ambala, Haryana, India

[email protected]

Follow Us