5 Gas Analyser
Product Code : EL-FTLE-10897
5 Gas Analyser (code EL-FTLE-10897) is a PC-based exhaust emission analyser used to diagnose engine faults such as fuel control problems, misfires, leaking head gaskets, no-starts, hard starts and EVAP system leaks. It measures HC, CO, CO2, O2 and NOx in parts per million, percentages or grams per mile or kilometre, updates from probe to screen in as little as 5 seconds and comes ready to run with cables, probes, connectors, hoses and its own power supply.
Get a quote: use the Add To Cart enquiry button below, or send your quantity and delivery location through the contact page.
Specifications
| Parameter | Detail |
|---|---|
| Use | Diagnosing fuel control problems, misfires, leaking head gaskets, no starts, hard starts and EVAP system leaks |
| Gases measured | HC, CO, CO2, O2 and NOx |
| Units | Parts per million or percentages; grams per mile / kilometre |
| Update rate | Probe to screen display as fast as 5 seconds |
| Supplied as | Ready-to-run test solution with all necessary cables, probes, connectors, hoses and its own power supply |
| Readings display | Numeric data, or graphs with large coloured traces |
| Viewing area | 1024 × 768 pixel (XGA) |
| PC interface | Serial port |
| Hold button | Cursor measurements of the last 2.5 minutes |
| Multi tool tab | Simultaneous viewing of emission data with data from other diagnostic tools |
| Data saving | Text file for future retrieval; JPEG image for e-mailing or documentation; can carry the workshop name and annotations |
| Remote monitoring | Web enabled, over LAN or internet |
| Recommended PC | |
| Screen | XGA (1024 × 768 pixel resolution) |
| Processor | 1 GHz |
| Memory | 256 MB RAM |
| Hard disk | 500 MB available space |
| Operating system | Windows XP through Windows 8.1, including Windows 8 and 8.1 tablets (Windows RT tablets not supported) |
| Port | Available RS-232 serial port or USB/RS-232 adaptor |
| Supply | |
| Product code | EL-FTLE-10897 |
| Supplier | Engineering Lab Equipment, Ambala, Haryana, India |
What Is the 5 Gas Analyser Used For?
Exhaust gas readings show how completely an engine is burning its fuel: high HC points towards misfire or unburnt fuel, high CO towards a rich mixture, and the balance of CO2 and O2 shows combustion efficiency and air leaks, while NOx reflects high combustion temperatures. The technician places the probe in the exhaust and connects the analyser to a PC through the serial port, then watches the five gas readings as numbers or graphs while the engine runs. The hold button lets the last 2.5 minutes be examined with cursors, and data can be saved as text or JPEG, or monitored remotely over a LAN or the internet.
What to Specify When Ordering
- Quantity — the number of analysers required.
Frequently Asked Questions
Which gases does the analyser measure?
It takes five gas measurements, HC, CO, CO2, O2 and NOx, and reports concentration in parts per million or percentages, with grams per mile or kilometre also supported.
What engine problems can it help locate?
Its readings help locate fuel control problems, misfires, leaking head gaskets, no starts, hard starts and EVAP system leaks, with probe-to-screen updates as fast as 5 seconds.
How does it connect to a computer?
The analyser interfaces to a PC through a serial port; the recommended PC has an XGA screen, a 1 GHz processor, 256 MB RAM, 500 MB free disk space and an RS-232 port or USB/RS-232 adaptor.
Which operating systems are supported?
Windows XP through Windows 8.1 are supported, including Windows 8 and 8.1 tablets, while Windows RT tablets cannot run the software.
How can test data be saved or shared?
Data can be saved as a text file for later retrieval or as a JPEG image for e-mailing or documentation, and the web enabled software allows remote monitoring over a LAN or the internet.
What is included in the package?
It comes as a ready-to-run test solution with all the necessary cables, probes, connectors and hoses, and it has its own power supply.
About the Supplier
Engineering Lab Equipment (Engineering Labs Equipment Pvt Ltd), Plot No. 43, Industrial Park, Sector 2, Growth Center, Saha, District Ambala, Haryana, India, supplies the 5 Gas Analyser together with its own fuel and oil testing apparatus for flash point, viscosity, distillation and calorific value. Engineering colleges, polytechnics, technical training institutes and research laboratories in India and overseas buy from the company, and tender and OEM enquiries are handled through the Tenders/OEM page.
Related Fuel Testing Equipment
- Ash Content Apparatus — 950 °C ceramic-chamber furnace for ash and filler content of polymer samples.
- Ramsbottom Carbon Residue Apparatus — five-bulb cast iron block coking furnace at 550 °C for Ramsbottom carbon residue.
- Orsat Gas Analysis Apparatus — gas analysis set with levelling bottle, water jacketed burette and three absorption pipettes.
See the full Fuel Testing Lab Equipment range or all Mechanical Engineering Lab Equipment.
Request a Quote
For this and other fuel testing lab equipment, schools and colleges can contact Engineering Lab Equipment, a manufacturer, supplier and exporter based in Ambala, India. For a price, send the number of analysers required and the delivery location through the contact page; the Add To Cart button on this page also adds the 5 Gas Analyser to an enquiry.