Cleveland Flash Point Apparatus
Product Code : EL-FTLE-10892
Cleveland Flash Point Apparatus (code EL-FTLE-10892) is a semi-automatic open cup tester used to determine the flash and fire points of petroleum products by the Cleveland open cup method, for products with flash points above 79 °C and below 400 °C except fuel oils. Its cup is electrically heated by a quartz tube furnace adjustable from 0 to 600 W, an electrically driven sweep arm applies the gas test flame, and the stainless steel unit runs on 220 V ±10%, 50 Hz.
Get a quote: use the Add To Cart enquiry button below, or send your quantity and delivery location through the contact page.
Specifications
| Parameter | Detail |
|---|---|
| Use | Determining flash and fire points of petroleum products by the Cleveland open cup method |
| Sample range | All petroleum products with flash points above 79 °C and below 400 °C, except fuel oils |
| Operation | Semi-automatic |
| Heating | Electrically heated cup; quartz tube furnace heating with no naked fire |
| Heating power | Continuously adjustable from 0 W to 600 W |
| Rate control | Variable control to set the temperature rise rate |
| Sweep arm | Button-operated, electrically driven |
| Test flame applicator | Applies the test flame automatically |
| Test flame gas | Mains gas, coal gas or other civil gas, or a portable gas tank |
| Flame diameter | 3.2 mm – 4.8 mm |
| Thermometer | -6 to 400 °C, the same as thermometer ASTM 11C |
| Flame extinguishing cover | Fitted |
| Construction | Desktop structure; stainless steel case, working table and furnace shell; fully self-contained |
| Power supply | AC 220 V ±10%, 50 Hz |
| Overall power consumption | ≤650 W |
| Operating ambient temperature | -10 to 50 °C |
| Relative humidity | ≤85% |
| Overall dimensions | 350 × 290 × 350 mm (thermometer not included) |
| Standards | GB/T3536-2008; AASHTO T48; ASTM D92; BS 2000 Parts 36 & 403 (obs); EN ISO 2592; FTM 791 1103.7; IP 36; JIS K2265; NF T60-118 |
| Product code | EL-FTLE-10892 |
| Supplier | Engineering Lab Equipment, Ambala, Haryana, India |
What Is the Cleveland Flash Point Apparatus Used For?
In the Cleveland open cup test the sample is heated in an open cup at a set rate while a small test flame is passed across its surface at intervals. The flash point is the lowest temperature at which the vapour flashes, and the fire point the higher temperature at which it goes on burning, which shows how safely heavier oils can be heated and handled. The operator fills the cup, sets the furnace heating power, connects the gas for the test flame and presses the button to drive the sweep arm, reading the thermometer at each point. The standards listed are GB/T3536-2008, AASHTO T48, ASTM D92, BS 2000 Parts 36 & 403 (obs), EN ISO 2592, FTM 791 1103.7, IP 36, JIS K2265 and NF T60-118.
What to Specify When Ordering
- Quantity — the number of testers required.
- Gas supply — mains gas, coal or civil gas, or a portable gas tank for the test flame.
Frequently Asked Questions
Which products can be tested?
It suits all petroleum products with flash points above 79 °C and below 400 °C, except fuel oils, and determines both flash and fire points by the Cleveland open cup method.
How is the cup heated?
The cup is electrically heated by a quartz tube furnace with no naked fire, and the heating power is continuously adjustable from 0 W to 600 W to set the temperature rise rate.
How is the test flame applied?
A button-operated, electrically driven sweep arm carries the test flame across the cup; the flame burns mains, coal or civil gas, or gas from a portable tank, at a diameter of 3.2 mm to 4.8 mm.
What thermometer is used?
The thermometer covers -6 to 400 °C, a span that takes in both the flash point and the fire point; the thermometer standard listed for it is ASTM 11C.
What power and operating conditions does it need?
It runs on AC 220 V ±10% at 50 Hz with an overall power consumption of no more than 650 W, in ambient temperatures of -10 to 50 °C and relative humidity up to 85%.
Which standards are listed for it?
The standards listed are GB/T3536-2008, AASHTO T48, ASTM D92, BS 2000 Parts 36 & 403 (obs), EN ISO 2592, FTM 791 1103.7, IP 36, JIS K2265 and NF T60-118.
About the Supplier
Engineering Lab Equipment (Engineering Labs Equipment Pvt Ltd), Plot No. 43, Industrial Park, Sector 2, Growth Center, Saha, District Ambala, Haryana, India, supplies the Cleveland Flash Point Apparatus together with its own fuel and oil testing apparatus for flash point, viscosity, distillation and calorific value. Engineering colleges, polytechnics, technical training institutes and research laboratories in India and overseas buy from the company, and tender and OEM enquiries are handled through the Tenders/OEM page.
Related Fuel Testing Equipment
- Abels Flash Point Apparatus — automated Abel flash point tester for -30 to 110 °C with thermal and ionization detection.
- Flash and Fire Point Apparatus — closed cup flash point tester with brass cup, sliding shutter cover and electric or gas heating.
- Automatic Smoke Point Apparatus — automated smoke point tester for kerosene and jet fuel with 0.1 mm flame height resolution.
See the full Fuel Testing Lab Equipment range or all Mechanical Engineering Lab Equipment.
Request a Quote
For this and other fuel testing lab equipment, schools and colleges can contact Engineering Lab Equipment, a manufacturer, supplier and exporter based in Ambala, India. Quotations are given on request: send the number of testers and the gas supply to be used for the test flame and your delivery location through the contact page, or add the Cleveland Flash Point Apparatus to the enquiry cart from this page.
Last updated: October 2026