Abels Flash Point Apparatus
Product Code : EL-FTLE-10889
Abels Flash Point Apparatus (code EL-FTLE-10889) is an automated tester used to determine the flash point of petroleum products and other liquids with flash points between -30 °C and 110 °C, mainly for shipping and safety regulations on flammable and combustible materials. It tests up to 110 °C, or down to -30 °C with an external chiller, using thermal and ionization detection, gas flame or electric ignition and a differential Pt-100 RTD probe, corrects results to 101.3 kPa and stores 200 results.
Get a quote: use the Add To Cart enquiry button below, or send your quantity and delivery location through the contact page.
Specifications
| Parameter | Detail |
|---|---|
| Use | Flash point determination of petroleum products and other liquids; testing flammable and combustible materials for shipping and safety regulations |
| Flash point range | -30 °C to 110 °C |
| Test range | Up to 110 °C; extended to -30 °C with a suitable external chiller |
| Test start | Flash cup filled with sample is mounted in the test position and a pre- or user-programmed test method is selected |
| Quick search method | For finding the flash point of samples not tested before |
| Detection | Dual, thermal and ionization, for testing all types of products |
| Ignition | Gas flame with safety cut-off device; electric ignition also available |
| Gas cut-off | Automatic, at the end of the test |
| Pressure correction | Results automatically corrected to standard pressure (101.3 kPa) |
| Temperature probe | Differential Pt-100 RTD, designed to duplicate the response time of a mercury-in-glass thermometer |
| Monitoring | Multiple sensors continually monitor instrument function; an error message is displayed if a problem is detected |
| Auto diagnostic | Included |
| Calibration parameters | Quick access |
| Data storage | 200 results |
| Software | Supervisor software included |
| Optional cryostat | Required for samples with a flash point below 40 °C |
| Optional low gas cartridge | For working in all types of environments |
| Electrical requirements | 115 V 50/60 Hz single phase, or 230 V 50/60 Hz single phase |
| Dimensions | 10.25 × 21 × 19.75 in (26 × 53.5 × 50 cm), l × w × h |
| Net weight | 44 lbs (20 kg) |
| Standards | IP 170; ISO 13016; NF T 66-009; DIN 51755; IP 33/59 & IS 1448 P:20 |
| Product code | EL-FTLE-10889 |
| Manufacturer | Engineering Lab Equipment, Ambala, Haryana, India |
What Is the Abels Flash Point Apparatus Used For?
The flash point is the lowest temperature at which the vapour above a liquid ignites briefly when a small flame is applied under set conditions, and it is used to class liquids as flammable or combustible for transport, storage and safety rules. The operator fills the flash cup, mounts it in the test position and selects a pre-programmed or user-programmed method, or the quick search method for a new sample; the tester heats the sample, applies the gas or electric ignition, detects the flash thermally and by ionization and corrects the result to 101.3 kPa. The standards listed are IP 170, ISO 13016, NF T 66-009 and DIN 51755, along with IP 33/59 and IS 1448 P:20.
What to Specify When Ordering
- Quantity — the number of testers required.
- Ignition — gas flame ignition or the electric ignition option.
- Power supply — the 115 V or the 230 V, 50/60 Hz single phase version.
- Optional items — whether the cryostat for samples with a flash point below 40 °C or the low gas cartridge is needed.
Frequently Asked Questions
What flash point range does the tester cover?
It covers petroleum products and other liquids with flash points between -30 °C and 110 °C; the unit tests up to 110 °C on its own and reaches -30 °C with a suitable external chiller.
How is a test started?
The flash cup is filled with sample and mounted in the test position, and a pre- or user-programmed method is selected; a quick search method finds the flash point of samples that have not been tested before.
How is the flash detected?
A dual detection system, thermal and ionization, picks up the flash and allows all types of products to be tested, while a differential Pt-100 RTD probe duplicates the response time of a mercury-in-glass thermometer.
Which ignition options are available?
Ignition is by gas flame, with a safety cut-off device and automatic gas cut-off at the end of the test; electric ignition is also available, and an optional low gas cartridge suits all types of environments.
How are results corrected and stored?
Results are automatically corrected to standard pressure (101.3 kPa), up to 200 results are stored, and supervisor software is included with the tester.
Which standards are listed for it?
The standards listed are IP 170, ISO 13016, NF T 66-009, DIN 51755, IP 33/59 and IS 1448 P:20.
OEM Manufacturer
Buyers of the Abels Flash Point Apparatus deal directly with its maker, Engineering Lab Equipment (Engineering Labs Equipment Pvt Ltd), whose works are at Plot No. 43, Industrial Park, Sector 2, Growth Center, Saha, District Ambala, Haryana, India. The company designs, makes and tests fuel and oil testing apparatus for flash point, viscosity, distillation and calorific value, supplies engineering colleges, polytechnics, technical training institutes and research laboratories in India and overseas, and builds to institution-specific requirements on request. Tender details are on the Tenders/OEM page.
Related Fuel Testing Equipment
- Flash and Fire Point Apparatus — closed cup flash point tester with brass cup, sliding shutter cover and electric or gas heating.
- Cleveland Flash Point Apparatus — semi-automatic Cleveland open cup tester for flash and fire points from 79 to 400 °C.
- Reid Vapour Pressure Apparatus — four-cylinder RVP bath with ±0.1 °C control and dual LED displays for fuel vapour pressure.
See the full Fuel Testing Lab Equipment range or all Mechanical Engineering Lab Equipment.
Request a Quote
For this and other fuel testing lab equipment, schools and colleges can contact Engineering Lab Equipment, a manufacturer, supplier and exporter based in Ambala, India. Quotations are given on request: send the number of testers, the ignition type and the 115 V or 230 V supply and your delivery location through the contact page, or add the Abels Flash Point Apparatus to the enquiry cart from this page.