Circulating Water Bath with Cooler Unit

Circulating Water Bath with Cooler Unit

Product Code : EL-CTLE-10367

Circulating Water Bath with Cooler Unit (code EL-CTLE-10367) is a digital water bath serving several tests, fitted with a cooler unit and re-circulating system, for conditioning asphalt specimens before Marshall and indirect tensile tests and for curing and storing cement specimens in water. It works from +5 to +60 °C, holds 40 l in a 550 × 360 × 200 mm polished stainless steel tank, is rated at 2000 W and weighs about 62 kg.

Get a quote: use the Add To Cart enquiry button below, or send your quantity and delivery location through the contact page.

Specifications

ParameterDetail
UseConditioning asphalt specimens in water for Marshall and Indirect Tensile tests; curing and storing cement specimens
Indirect tensile conditioning5 °C, or from 5 to 25 °C, as prescribed by EN 12697-23; obtained with the cooling system
Other conditioning25 to 60 °C, as required by other standards
Cement curing40 × 40 × 160 mm cement specimens cured in water; hydrated samples stored at 20 °C
Internal surfacesPolished stainless steel
Outer caseSheet steel, insulated
Cooler unitLocated under the water bath, with refrigeration compressor
Re-circulationRe-circulating unit for temperature uniformity
Temperature controlTwo-channel electronic thermo regulator for heating and cooling, with digital display; set temperature maintained automatically
Power2000 W
Temperature range+5 to +60 °C
Accuracy± 1%
Capacity40 l
Inside dimensions550 × 360 × 200 mm
Outside dimensions830 × 480 × 950 mm
WeightApprox. 62 kg
StandardsEN 12697-34, ASTM D1559, ASTM D5581, AASHTO T245, EN 12697-12, EN 12697-23, ASTM D6927
Product codeEL-CTLE-10367
ManufacturerEngineering Lab Equipment, Ambala, Haryana, India

What Is the Circulating Water Bath with Cooler Unit Used For?

Strength results on bituminous mixtures depend strongly on temperature, so asphalt specimens are brought to the test temperature in water before Marshall or indirect tensile testing, and cement specimens likewise need a stable water temperature while they cure. The operator sets the temperature on the digital regulator; the heater or the cooler unit beneath the bath brings the water to it, and the re-circulating unit keeps it even throughout the tank. Asphalt specimens stay in the bath for the conditioning period and go straight to the test, while 40 × 40 × 160 mm cement prisms can be cured and stored in water at 20 °C.

What to Specify When Ordering

  • Quantity — the number of water baths required.
  • Application — asphalt specimen conditioning, cement specimen curing or both, with the temperatures needed.

Frequently Asked Questions

Which tests is the Circulating Water Bath with Cooler Unit used for?
Its main uses are bringing asphalt specimens to temperature in water before Marshall and indirect tensile testing, and curing 40 × 40 × 160 mm cement specimens in water with storage at 20 °C.

Why does the bath need a cooler unit?
Indirect tensile conditioning of bituminous mixtures calls for water at 5 °C or from 5 to 25 °C, often below room temperature, and the cooling system makes these temperatures obtainable.

What temperature range and capacity does it have?
The bath works from +5 to +60 °C with an accuracy of ± 1%, holds 40 l, and has inside dimensions of 550 × 360 × 200 mm.

How is the temperature controlled?
A two-channel electronic thermo regulator with digital display controls both heating and cooling and maintains the set temperature automatically, while a re-circulating unit keeps it uniform.

How is the bath constructed?
Polished stainless steel lines the tank inside an insulated sheet steel case, and the cooler unit with its refrigeration compressor sits under the bath; the unit measures 830 × 480 × 950 mm and weighs about 62 kg.

Which standards are listed?
The standards listed are EN 12697-34, EN 12697-12, EN 12697-23, ASTM D1559, ASTM D5581, ASTM D6927 and AASHTO T245; the power rating is 2000 W.

OEM Manufacturer

Buyers of the Circulating Water Bath with Cooler Unit deal directly with its maker, Engineering Lab Equipment (Engineering Labs Equipment Pvt Ltd), whose works are at Plot No. 43, Industrial Park, Sector 2, Growth Center, Saha, District Ambala, Haryana, India. The company designs, makes and tests cement testing equipment such as Vicat and Blaine apparatus, moulds, mixers and curing equipment, supplies engineering colleges, polytechnics, technical training institutes and research laboratories in India and overseas, and builds to institution-specific requirements on request. Tender details are on the Tenders/OEM page.

Related Cement Testing Equipment

See the full Cement Testing Lab Equipment range or all Civil Engineering Lab Equipment.

Request a Quote

For this and other cement testing lab equipment, schools and colleges can contact Engineering Lab Equipment, a manufacturer, supplier and exporter based in Ambala, India. Quotations are given on request: send the number of baths and the conditioning or curing temperatures needed and your delivery location through the contact page, or add the Circulating Water Bath with Cooler Unit to the enquiry cart from this page.